Test Instruments
Maximum display range and accuracy for digital multimeters and digital clamp meters and environmental meters
Indicates the least significant digit.
It represents the error used for processing fractions when
converting from analog to digital.
MT-1860/1820: the maximum display range is "5999".
MT-1232: the maximum display range is "3999".
MT-1280/1270/1210: the maximum display range is "1999".
For example of measuring resistance at MT-1232
When ACV measument using the MT-1270, the maximum display
value is 199.9V, minimum display value is 0.01V.
Example
The accuracy of the AC200 V reading is ±(0.8%rdg+5dgt).
when measuring AC100V, the accuracy reading display range is 100.9~99.15.
100V±(0.8%+5dpt)
=100+(0.80+0.05) ~100-(0.80+0.05)
=100.9~99.15
Maximum display range
Accuracy
Resistance
4000k 4.000M
4000 4.000k
40 40.00
Display
The range is automatically switched so that the
display unit is M or k
The reading is display with three digits.
rdg(reading)
The value on the digital display,readout.
dgt(dilgit)
Frequency
Hz
Capacitance
Inductor check
Temperature ˚C/˚F
measurement
˚C
˚F
Temperature ˚C
measurement
˚C
AP
OFF
Auto power off
Diode test
0
ADJ
Zero-ohm adjuster
hFE
Transistor hEF
test
CONT.
LED
Continuity check
REL
Relative reference
LED
LED test
DC current
A
A
AC current
V
DC voltage
V
AC voltage
Resistance
Battery check
Continuity buzzer
USB connector
USB
OUT
Output terminal
HOLD
Data hold
Hz
Duty
Duty cycle
MAX
MIN
Maximum/Minimum
value
Backlight
MAX
HOLD
Maximum value hold
Most of test instruments are
approved by CE EN61010-1 CATII/
CATIII test .
CAT. II Primary circuits or equipments
connected to low voltage
facilities, such as a standard
wall outlet.
CAT. III Equipment used for
measurement in building
facilities, distribution boards,
and circuit breakers.
SI prefixes
Symbol Prefixes
Decimal
Long Scale
G
M
K
m
µ
n
p
Short Scale
Units frequently used
1X1,000,000,00 1X10
9
GHz
M , MHz
k , kV, kW,kHz
mV, mA, mW, mF, mH
µV, µA, µW, µF, µH
nA, nF, nH
pF, pH
1X10
6
1X10
3
1X10
-3
1X10
-6
1X10
-9
1X10
-12
1X1,000,000
1X1,000
1/1,000
1/1,000,000
1/1,000,000,000
1/1,000,000,000,000
giga
mega
kilo
milli
micro
nano
pico
Low battery
Hygrometer
RH
Light meter
Lux
Thermometer
Air
Sound level
meter
dB